• 15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
  • 15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
  • 15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
  • 15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
  • 15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
  • 15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer

15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer pictures & photos
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
US $3,500-10,600 / Unit
Min. Order: 1 Unit
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MG-10CD
Selected Voltage
3pH-220V/240V/380V/415V/440V/460V/480V-50Hz / 60Hz
Compressor Number
2
Noise Level
Low
Application Fields
Winery, Brewery, Beverage
Application Machine
Precision Machine Tool
Certification
RoHS, UR, ISO, CE
Condition
New
Cooling Capacity
5 Tons@ -5c
Compressor Brand
Copeland, Panasonic, Danfos
Compressor Type
Hermetic Scroll
Refrigeration Circuit
2
Evaporator Type
Closed Shell and Tube or SS304 Tank with Coil
Temperature Control
-5deg C~ +30deg C
Condenser
Finned Copper Tube Aluminum Fins
Compressor HP
10HP
Transport Package
Plywood Case(Not Need Fumigation)
Trademark
MGREENBELT
Origin
Shandong, China
HS Code
8418699090
Production Capacity
500 Units/Year

Packaging & Delivery

Package Size
1600.00cm * 700.00cm * 1600.00cm
Package Gross Weight
450.000kg

Product Description

 
15HP 20BBL -5C Brewing System Cooling Propylene Glycol Chiller for beer
 
Some people will always ask why glycol is used in your glycol chiller?

The use of an industrial inhibited glycol and water mixture is recommended in most water chiller systems.

Ethylene and Propylene are the two standard types of inhibited glycols commonly used. As we all know if the water temperature goes down to 0ºC, the water will be frozen to be ice.

So the main job of glycol is to prevent freezing of the process fluid and ensure consistent flow at the operating temperature.

A glycol chiller is a special refrigeration system, mostly used to cool a variety of liquids including alcohol, chemical liquid, and other beverages.

Using a glycol chiller allows producers to lower the temperature of the product dramatically within a limited time, depending on the production requirements.

For glycol chillers, Propylene glycol and water mixture play an important role in the application of a glycol chiller, more so the working principle.

For chilling in brewing, glycol chiller plays an important part in the refrigeration.

For brewing industries, There are some processes where decreasing or maintaining temperature is mostly important - like crash cooling beer after fermentation, keeping a steady temperature during fermentation (which generates heat), or cooling the wort after an initial boiling process.

Mgreenbelt offers a variety of glycol chillers from cooling capacity 5Ton to 180Ton and glycol temperature at -5ºC to -35ºC.

These full-range glycol chiller models are most suitable for certain critical industrial applications including cooling and dispensing beer, water, chemical liquid and other beverages where there is limited refrigeration.

Mgreenbelt glycol chillers can be added to an existing remote glycol system for additional cooling capacity.

There are 4 stages of glycol chiller temperature controlling range, 0ºC to -10ºC, -10ºC to-20ºC and -20ºC to -30ºC. If you have special requirements, we can make -35ºC glycol chiller. But remember that the temperature stability is +/-2ºC.
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer


Description of Air cooled glycol chiller
25HP 25BBL Brewhouse Wort and Fermentation Tanks Cooling Air Cooled Glycol Chiller
Our industrial using air cooled chiller adopt famous brand components to ensure the high quality and good performance for your usage. Popular PLC control system which show out working condition of each parts, and touch screen operate,to be controlled easily and powerful. Main four parts below:

1) Compressor: scroll type, brand Copeland, Danfos, Panasonic

2) Evaporator; SS304 tank with coil or Shell and tube or Plate Heat exchanger

3) Condenser: Finned cooper tube with low noise axial fan

4) Tailor made power supply: 3phase,208-240v,380-415v,440v-460v,50hz or 60hz
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer


Glycol Chiller for Beer

There are four main applications for glycol chillers in breweries: Wort Cooling, Cold Water Storage Tanks, Brite Tanks/Fermenters, and Refrigeration. The size of your brewery chiller will be determined by the sum of each of these heat load requirements. Calculate Knockdown (or Pull Down/Crashing) Load for Wort Cooling.
Glycol chiller used for
Breweries. In breweries, the glycol chiller is used for cooling the wort,for controlling the fermentation process and speed.
Wineries. Glycol chillers are widely used in the fermentation process, cold stabilization can be also used for room cooling purpose
Technical Seet
Air Cooled glycol chiller from 3hp to 50hp,
Supply glycol water cold temperature -15c,-10c,-5C, as production required.
 Model MG-15CL MG-20CL MG-25CL MG-40CL MG-50CL
Cooling capacity  0ºC kw 33.4 44.2 50.5 87.7 110.6
 -5ºC kw 28.4 37.6 43 74.5 94
 Power kw 15.84 20.51 23.52 40.18 47.92
 Power Supply 3PH-380V-50HZ
   Type R22/R407C
Refrigerant Control Thermostatic expansion valve
Compressor  Type Hermetic scroll type
 Power kw 4.4*3 8.7*2 10.2*2 8.7*4 10.2*4
Evaporator Type SS Tank with coil or Heat exchanger plate
m³/h
Flow
0ºC 6.33 8.37 9.57 16.62 20.96
-5ºC 5.84 7.73 8.85 15.33 19.34
Capacity L 270 350 350 580 580
Pipe diameter DN40 DN40 DN40 DN65 DN80
Condenser  Type High efficiency hydrophilic aluminum foll finned type
Power kw 0.55*2 0.78*2 0.78*2 0.78*4 0.78*4
pump  Type  Centrigual water pump
 Power kw 1.5 1.5 1.5 2.2 2.2
 lift m 20 20 20 20 19
Protection System Compressor overheat protection, high/low pressure protection,phase missing/sequence protection, flow rate protection, anti-frozen protection.
Dimension  L mm 1800 2100 2100 2000 2000
 W mm 1000 1000 1000 2000 2000
 H mm 1600 1700 1700 1750 1750
 Wight kg 750 850 900 1350 1600
 Model MG-3C MG-5C MG-6C MG-8C MG-10C MG-12C
Cooling capacity  0ºC kw 6.8 10.5 12.2 16.2 22.8 24.8
 -5ºC kw 5.7 8.9 10.3 13.8 19.3 21
 Power kw 3.45 5.45 6.31 8.22 10.54 12.33
 Power input 3PH-380V-50HZ
Refrigerant  Type R22/R407C
Control Thermostatic expansion valve( Capillary)
Compressor Type  Hermetic scroll type
 Power kw 2.84 4.36 5.2 3.5*2 4.4*2 5.2*2
Evaporator  Type  SS Tank with coil or Shell and tube
m³/h
Flow
0ºC 1.29 1.99 2.31 3.07 4.32 4.70
-5ºC 1.17 1.83 2.12 2.84 3.97 4.32
Capacity L 50 70 70 120 200 200
pipe diameter of chilled water DN25 DN25 DN25 DN32 DN32 DN32
Condenser Type High efficiency hydrophilic aluminum foll finned type
 Power kw 0.19 0.52 0.52 0.24*2 0.46*2 0.46*2
pump  Type Centrigual water pump
Power kw 0.37 0.55 0.55 0.55 0.55 0.55
lift m 24 25 24 20 20 20
Protection System Compressor overheat protection, high/low pressure protection,phase missing/sequence protection, flow rate protection, anti-frozen protection.
Dimension L mm 1100 1200 1200 1400 1560 1560
 W mm 600 600 600 800 850 850
H mm 1100 1100 1100 1400 1500 1500
 Wight kg 150 200 230 310 450 500
Air Cooled glycol Chiller Technical Features 
15HP 20BBL -5C Brewing System Cooling Propylene Glycol Chiller for beer
1.No refurbished , new and original scroll type compressors, famous brand Copeland, Danfos, and Panasonic, built in multi safety protection, low noise, energy saving and stable.
2. Adpopt Schneier, Siemens, AB electrical components, featuring stability and long service life.
3. Italian water pump with big flow, low power to save energy, high efficiency and durability.
4. Imported precise digital temperature controller with LCD display, controlling the water temperature as accurate as ±1ºC . Auto test and analysis function by displaying working condition in English for easy operation and monitoring.
5. Stainless steel buffer tank is available, and built in auto filling water devices, convenient for clean and maintenance.
6. High efficiency shell and tube type evaporator, to cool tank outside.
7.Air cooled industrial chiller equipped with finned copper by the warped and ranked copper pipe, to release the heat into air to cool down the coolant temperature.
8.Optional environmental protection refrigerant R404A, R134a, R407c, R410a
9.Customized chiller with special power supply voltage.
10. Outlet glycol/water temperature -10 deg C to +30deg C, high precision to ±1 deg C.
 
Images of Air Cooled Glycol Chiller
40HP GLYCOL CHILLER, 4X10HP 
20HP:2X10HP GLYCOL CHILLER, 25HP: 2X12.5HP AIR COOLED GLYCOL CHILLER FOR BREWERY
30HP GLYCOL CHILLER
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer


 
 
Working Site and Application Industry
MGreenbelt water chillers are apply widely in the Microbreweries, confectionary, bakeries, distilleries, wineries, bottling, corbonation, vegetable, meat and fish processing, etc , which requested by the modernized machinery production, and greatly improved the production efficiency and product quality. MGREENBELT Industrial chiller is a good partner for the modernized industry , which feather as easy to operate with reasonable design, high quality and complete range of specifications. 
R410a Refrigerant 20 tons 40HP Air Cooled Glycol Chiller for Brewery
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
About US

Mgreenbelt is a professional refrigeration equipment manufacturer, producing air cooled chiller, water cooled chiller, glycol chiller for various industrial applications; we was established since 2003, with 34,000 squre meter workshop, all of our product with CE certificate, can supply the SASO, SGS, COC,SABER, UL,etc.

Package:

Packaging : We consider all different potential situation in the delivery, so we use every prevention measures to avoid any potential inconvenience or trouble
a.Bulk cargo: Standard wooden case which can avoid any clash during the sea or air transportation in case of causing damage to the surface of our products.
b. Container cargo: the equipment will be bound firmly and won't easily swing to the side, or up, or down.

Shipping: Deliver from Qingdao, Shanghai, Guangzhou, Tianjin, Hangzhou, within 15-35 days after the payment.
FAQ
1. How about the quality of your product?
· Our products manufactured strictly according to national and international standard. 
· We have CE, ISO, UL, SABER, CA certification.
· We take a test on every product before delivery.

2. What's the order process?
.Inquiry---provide us all clear requirements.
.Quotation---quotation form with all clear specifications.
.Contract confirmation---provide correct contract details.
.Payment terms--- T/T 30% in advanced, balanced before shipment.
.Production---mass production
.Testing: 8hours, to ensure the quality of the machine
.Shipping--- by sea, train, air or courier. Detailed picture of package will be provided.
.Installation

3.What's the warranty? 
1 year warrenty for free if confirmed by both side damage in the quality reason. 

4. How to get a prompt quotation?
When you send the inquiry to us, pls kindly send it with below technical  information.
1)water chiller type: Air cooled or water cooled
2)Cooling capacity:       _____    Kcal/hr  or   _____KW
3)Refrigerant:  R22 or others
4) Voltages and Frequency :   ______V/PH/HZ
5) Application industry:

5. How can I place an order? 
Please send inquiry to us ! Click " Contact Now"

As a professional industrial chiller manufactuer and solution provider , we can supply kinds of chillers to meet your different cooling requirement, if the chillers above is not workable for you, please feel free send needs to us directly.
Contact Person: Libra Zhang

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer pictures & photos
15HP 20HP -5c Brewing System Cooling Propylene Glycol Chiller for Beer
US $3,500-10,600 / Unit
Min. Order: 1 Unit
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
23
Year of Establishment
2000-04-19