100HP 200HP Air Cooled Industrial Water Chiller For HVAC Air Conditioner
As a professional water chiller manufactuer in China, we can supply kinds of chiller solution according to your different working need, OEM is accept, if this series is not workable for you, please feel free send news to us.
Our Product Range
(1).The Temperature Range:-40ºC to +35ºC.
(2).Cooling Capacity Range: 2 RT to 500RT / 7 kw to 1750kw / 6020Kal to 1505000Kal
(3). The Refrigerant: R22/R404a/R134a/R507c.
(4). We can also produce the chiller according to your requirements.
1. Technical Parameter for 100HP 200HP Air Cooled Industrial Water Chiller For HVAC Air Conditioner
Air Cooled Screw Chiller Normally Temperature Series( Single System) |
Model |
MG-150C |
MG-170C |
MG-250C |
MG-300C |
MG-450C |
MG-530C |
Cooling Capacity |
USRT |
40.4 |
46.9 |
76.8 |
93.8 |
127.9 |
150.7 |
Kcal/h |
122120 |
141900 |
232200 |
283800 |
387000 |
455800 |
KW |
142 |
165 |
270 |
330 |
450 |
530 |
Power |
3PH-380V-50Hz |
Refrigerant |
Type |
R22/R407C |
Control |
Thermostatic expansion valve |
Comperssor |
Type |
semi-closed screw type |
kw Power |
48 |
55 |
86 |
106 |
142 |
165 |
Start |
Y-△ |
Capacity |
25%-50%-75%-100% |
Evaporator |
Type |
High efficiency copper tube shell and tube type |
m³/h Flow |
24 |
28 |
46 |
57 |
77 |
91 |
Inlet/outlet |
DN80 |
DN80 |
DN80 |
DN80 |
DN100 |
DN100 |
Condenser |
Type |
High efficiency hydrophilic aluminum foll finned type |
m³/h Flow |
50000 |
60000 |
100000 |
120000 |
150000 |
180000 |
Protection System |
Compressor overheat protection, high/low pressure protection,phase missing/sequence protection, flow rate protection, anti-frozen protection. |
Dimension |
L(mm) |
3200 |
3300 |
4400 |
3850 |
4750 |
5850 |
W(mm) |
1450 |
2300 |
2300 |
2200 |
2200 |
2200 |
H(mm) |
2150 |
2400 |
2400 |
2350 |
2450 |
2450 |
Wight |
kg |
2300 |
2480 |
3800 |
3300 |
4000 |
5000 |
2.100HP 200HP Air Cooled Industrial Water Chiller For HVAC Air Conditioner Diagram
3. Specification Details Images
100HP 200HP Air Cooled Industrial Water Chiller For HVAC Air Conditioner
Hanbell / Bitze r Compressor
The choice of Taiwan HANBELL or Germany Bitze r screw compressor, the use of high-quality bearings, standard operating conditions under the design of the operating life of more than 50,000 hours, optional single compressor / double compressor.
FCNP Pump Industry
FCNP Stainless steel pump. With high lift, large flow, low energy consumption, smooth and reliable operation, high efficiency and lower fault, low vibration noise, long life and other advantages, to ensure that water quality away from corrosion.
Some merchants in order to save costs, will be equipped with poor performance of the water pump, will cause the machine cooling effect is not good, operation is unstable, the chance of repair is high and so on. We use FCNP stainless steel pumps to make the machine more durable and better.
Evaporator core corrosion resistance, good thermal conductivity, high temperature, heat exchange performance, non-polluting media (non-toxic), not easy to scale, non-magnetic, not easy to leak. The inner core adopts a high-strength sealing structure, which is sealed well and increases heat exchange performance.
Microcomputer Control System Or SIMENS PLC Control System
The intelligent control system of microcomputer is precisely controlled, Simple operation, intelligent start and stop, Precision temperature control within 5 to 45 degrees of arbitrary adjustment, LCD display, all kinds of faults at a glance, Monitor ingends in real time, Multiple protection features, The Chinese and English interface sits to switch, To meet the needs of different users, Easy to operate.
Schneide r Electrical Systems
Protection system built-in compressor superload protector, circulating water pump superload, system high and low pressure protector, compressor start electronic time delay, German SIEMENS electronic products, with a sound electrical protection system.
4. Water Chiller Show
Air Cooled Screw Water Chiller
5.Chiller Application
Why your plastic machines need plastic chillers?
Plastic chillers are always used to cooling the hot plastic that is injected from injection molding to maximize productivity and improve quality; By cooling down the plastic process equipment that is used to produce plastic products, such as hydraulics of the molding machine, gearbox, and barrel of the injection molding machine, to save energy and extend the lifetime of the machine; One of the most important steps in the mold making process is a consistent and proper cooling cycle; This is due to the fact cooling rates can have a significant influence on the overall quality of the finished item; The cooling cycle must remain consistent throughout the entire production run to ensure all items are equal in quality; Plastic chiller- includes air chiller and water chiller will provide this consistent cooling water during the process.
This is the most advantage and purpose of using a plastic chiller.
6.Model selection parameter
If you are a plastic injection/ extruder, molding industry user, please tell us:
(1). What's your plastic machine type, what's the capacity.
(2). What's the materials you are using, PVC, PE, PP, or others.
Then we will suggest your a right model.
If you are used for other industry, please provide following parameters, MGREENBELT sales will choose the suitable machine for you.
(1).What is the maximum cooling capacity(KW/kcal/h) you need?
(2).What's your inlet and outlet temperature need?
(3).What's your voltage ?Including frequency and Hertz
(4).What's your choice of refrigerant? R22/R407c/R134a or others?
(5).What is the max ambient temperature in your country?
How can I place an order?
1. Please send inquiry to us ! Click " Contact Now"
2. Contact us by call, please find our information at " Contact Us" Mis Jackie QI