• R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
  • R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
  • R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
  • R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
  • R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
  • R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery

R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery pictures & photos
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
US $8,960-13,280 / Unit
Min. Order: 1 Unit
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MG-40C(D)
Selected Voltage
3pH-220V/240V/380V/415V/440V/460V/480V-50Hz / 60Hz
Compressor Number
4
Noise Level
Ordinary
Application Fields
Winery, Brewery, Beverage
Application Machine
Precision Machine Tool
Certification
RoHS, UR, ISO, CE
Condition
New
Cooling Capacity
25600 BTU/ 20 Tons /74.5kw
Compressor Brand
Copeland,Danfos
Compressor Type
Hermetic Scroll
Refrigeration Circuit
4
Evaporator Type
Closed Shell and Tube or SS304 Tank with Coil
Temperature Control
-5deg C~ +30deg C
Condenser
Finned Copper Tube Aluminum Fins
Air Volume
50000m3/Hr
Compressor HP
40HP
Transport Package
Plywood Case(Not Need Fumigation)
Specification
2500x14200x1800mm
Trademark
MGREENBELT
Origin
Shandong, China
HS Code
8418699090
Production Capacity
500 Units/Year

Packaging & Delivery

Package Size
2500.00cm * 1500.00cm * 2100.00cm
Package Gross Weight
1500.000kg

Product Description

R410a Refrigerant 20 tons 40HP Air Cooled Glycol Chiller for Brewery
 
Why choose MGREENBELT as your Chiller? 
R410a Refrigerant 20 tons 40HP Air Cooled Glycol Chiller for Brewery
(1).18 years of water chiller manufacturing experience; MGREENBELT is a leader of water chiller manufacture with rich experience
(2).14 month warranty time: MGREENBELT provide 14-month warranty for standard chillers can extend to 14 months covered all water chillers
(3).Famous brand spare parts: Each water chiller from MGREENBELT using world famous brand refrigeration spare parts
(4).Technical support& Training service: MGREENBELT can provide all clients water chiller installation and commission service
(5).1 Hours troubleshooting: In case of any water chiller error or alarm, MGREENBELT will give a quick response within 1 Hours to help to solve the problem
(6).Lifetime service: MGREENBELT promise clients to give all water chiller unit whole lifetime service free of charge.
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
Description of MGREENBELT chiller

Our industrial using air cooled chiller adopt famous brand components to ensure the high quality and good performance for your usage. Popular PLC control system which show out working condition of each parts, and touch screen operate,to be controlled easily and powerful. Main four parts below:

1) Compressor: scroll type, brand Copeland, Danfos, Panasonic

2) Evaporator; SS304 tank with coil or Shell and tube or Plate Heat exchanger

3) Condenser: Finned cooper tube with low noise axial fan

4) Tailor made power supply: 3phase,208-240v,380-415v,440v-460v,50hz or 60hz

Glycol Chiller for Beer

There are four main applications for glycol chillers in breweries: Wort Cooling, Cold Water Storage Tanks, Brite Tanks/Fermenters, and Refrigeration. The size of your brewery chiller will be determined by the sum of each of these heat load requirements. Calculate Knockdown (or Pull Down/Crashing) Load for Wort Cooling.
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
Design:

(1). Electrical waterproof IP55 grade, chiller could be placed outdoor without shelter.

(2)  Design working condition ambient temperature from -20C degree to +50C degree.

(3). Working condition: good air circulation place to discharge the heat.

(4). Remote and local control available, chiller with stop/off function remote and alarm remote optional.

(5). Power off - Auto strart up turn on function supported. 

(6). Inlet and outlet pipe stainless steel; 
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery


 
Technical Specification

Air Cooled glycol chiller from 3hp to 50hp,
Supply glycol water cold temperature -15c,-10c,-5C, as production required.
Air Cooled glycol Chiller 
Model MG-15CL MG-20CL MG-25CL MG-30CL MG-40CL MG-50CL
15HP 20HP 25HP 30HP 40HP 50HP
Cooling capacity Kcal/h 24461 32385 37037 48923 64168 107844
kw 28.4 37.6 43 56.8 74.5 94
Input power kw 15.84 20.51 23.52 31.81 40.2 47.9
Outlet water temperature -5ºC~30ºC
Power supply 3PHASE - 220V/380V/415V/440V/480V-50HZ/60HZ
Refrigerant  Type R-22 or R407c or R404a or R410a or R134a
Control type Thermostatic expansion valve
Compressor Type Scroll Type
 Power(kw) 13.2 17.5 20.4 26.1 34.8 40.8
Evaporator  Type  Tank with coil or Shell and tube or Brazed plate heat exchanger(BPHE)
Water flow(m³/h) 5.84 7.73 8.85 11.68 15.3 19.3
Fitting pipe(mm) DN40 DN40 DN40 DN65 DN65 DN80
Condenser Type Finned Copper tube +low noise air fans
Air flow(m³/h) 15000 20000 25000 30000 40000 50000
Water pump  Power(kw) 1.5 1.5 1.5 2.2 2.2 4
Lift(m ) 20 20 20 20 20 20
Dimension  L(mm) 1800 2000 2000 2500 2350 2000
W(mm) 1000 1000 1000 1200 1460 2000
H(mm) 1600 1700 1700 1800 1900 1750
Net Weight kg 750 850 900 1150 1350 1600
 
Air Cooled glycol Chiller ( -5deg C )
Model MG-3CL MG-5CL MG-6CL MG-8CL MG-10CL MG-12CL
3HP 5HP 6HP 8HP 10HP 12HP
Cooling capacity Kcal/h 4910 7665 8871 11886 16623 18087
kw 5.7 8.9 10.3 13.8 19.3 21
Input power kw 3.45 5.45 6.31 8.22 10.54 12.33
Outlet water temperature -5ºC to 30ºC
Power supply 3PHASE-220V/380V/415V/460-50HZ/60HZ
Refrigerant  Type R22/R407C/R404A
Control type Thermostatic expansion valve
Compressor Type Hermetic scroll type
 Power(kw) 2.84 4.36 5.2 7 8.8 10.4
Evaporator  Type SS Tank with coil or Shell and tube or Brazed plate heat exchanger
Water flow(m³/h) 1.17 1.83 2.12 2.84 3.97 4.32
Fitting pipe(mm) DN25 DN25 DN32 DN32 DN32 DN32
Condenser Type Finned Copper tube +low noise air fans
Air flow(m³/h) 3000 5000 6000 8000 10000 12000
Water pump Type Centrifugal water pump
 Power(kw) 0.37 0.75 0.75 0.75 0.75 0.75
Lift(m ) 20 20 20 20 20 20
Dimension  L(mm) 1200 1300 1300 1400 1560 1560
W(mm) 600 650 650 800 850 850
H(mm) 1100 1200 1200 1400 1500 1500
Net Weight kg 150 200 230 310 450 500
 
Images of Air Cooled Water Chiller
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery

 
Working Site and Application Industry
MGreenbelt water chillers are apply widely in the Microbreweries, confectionary, bakeries, distilleries, wineries, bottling, corbonation, vegetable, meat and fish processing, etc , which requested by the modernized machinery production, and greatly improved the production efficiency and product quality. MGREENBELT Industrial chiller is a good partner for the modernized industry , which feather as easy to operate with reasonable design, high quality and complete range of specifications. 
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
Package:

Packaging : We consider all different potential situation in the delivery, so we use every prevention measures to avoid any potential inconvenience or trouble
a.Bulk cargo: Standard wooden case which can avoid any clash during the sea or air transportation in case of causing damage to the surface of our products.
b. Container cargo: the equipment will be bound firmly and won't easily swing to the side, or up, or down.

Shipping: Deliver from Qingdao, Shanghai, Guangzhou, Tianjin, Hangzhou, within 15-35 days after the payment.
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery

FAQ
1. Are you manufacturer or Trade Company?
We are OEM professional factory, founded in 2003.

2. How to get a prompt quotation?

When you send the inquiry to us, pls kindly send it with below technical  information.
1)water chiller type: Air cooled or water cooled
2)Cooling capacity:       _____    Kcal/hr  or   _____KW
3)Refrigerant:  R407c, R410A or others
4) Voltages and Frequency :   ______V/PH/HZ
5) Application Industry:______
As a professional industrial chiller manufactuer and solution provider , we can supply kinds of chillers to meet your different cooling requirement, if the chillers above is not workable for you, please feel free send needs to us directly.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery pictures & photos
R410A R513A 5 Tons 15 Tons Air Cooled Glycol Chiller for Brewery
US $8,960-13,280 / Unit
Min. Order: 1 Unit
Diamond Member Since 2020

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
23
Year of Establishment
2000-04-19