Air cooled scroll water chiller 5deg C~ 30deg C | ||||||||||
Model | MG-5C | MG-10C(D) | MG-12C(D) | MG-15C(D) | MG-20C(D) | MG-25C(D) | MG-30C(D) | MG-40C(D) | ||
Cooling capacity | Kcal/h | 11266 | 24510 | 26660 | 35948 | 47558 | 54352 | 71896 | 94256 | |
KW | 13.1 | 28.5 | 31 | 41.8 | 55.3 | 63.2 | 83.6 | 109.6 | ||
Tons | 3.72 | 8.10 | 8.81 | 11.89 | 15.72 | 17.97 | 23.77 | 31.16 | ||
Input power | kW | 5.61 | 10.83 | 12.53 | 16.31 | 21.27 | 24.35 | 32.33 | 41.66 | |
Outlet water temperature | 5°C -35°C | |||||||||
Power supply | 3PHASE-220/380V/415v/460v-50HZ/60HZ | |||||||||
Refrigerant | Type | R22/R407C/R410A | ||||||||
Control type | Thermostatic expansion valve | |||||||||
Compressor | Type | Hermetic Scroll Type | ||||||||
Power(kw) | 4.54 | 4.54*2 | 5.4*2 | 4.54*3 | 9.05*2 | 10.6*2 | 9.05*3 | 9.05*4 | ||
Evaporator | Type | Stainless Steel Tank with Coil type or Shell and tube | ||||||||
Water flow(m³/h) | 2.25 | 4.89 | 5.31 | 7.17 | 9.48 | 10.83 | 14.33 | 18.79 | ||
Capacity(Lts) | 70 | 200 | 200 | 270 | 350 | 350 | 450 | 580 | ||
Fitting pipe(mm) | DN25 | DN32 | DN32 | DN40 | DN40 | DN40 | DN65 | DN65 | ||
Condenser | Type | Finned Copper tube +low noise air fans | ||||||||
Air volume(m³/h) | 5000 | 10000 | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | ||
Water pump | Power(kw) | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 3 | |
Lift(m ) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 | ||
Dimension | L(mm) | 1300 | 1560 | 1560 | 1800 | 2100 | 2100 | 2500 | 2350 | |
W(mm) | 650 | 850 | 850 | 1000 | 1000 | 1000 | 1200 | 1460 | ||
H(mm) | 1200 | 1500 | 1500 | 1600 | 1700 | 1700 | 1800 | 2000 | ||
Weight | KG | 200 | 450 | 500 | 750 | 850 | 900 | 1150 | 1350 | |
NOTE 1.Normal conditions:Chilled water inlet temp is 12ºC,outlet temp is 7ºC,Ambient temp35ºC; 2.Temperature condtion:Chillerd water range is 7ºC--30ºC,This series of unit requires the chient to use the liquid with the freezing point below the required temperature as the refrigerant. 3.Input power:3P-380V-50HZ,Allowable buctuate voltage:±10%.Allowable voltage difference in phase:±2% 4.Actual head lift is pump head lift minus the machine internal head loss(1mH2O=9.8KPa); 5.The above parameters are based are Refrigerant R22,for other parameters of Refrigerant R134A,R407C ect.refrigerants,plcontact us. 6.Due to technology updating, size meters listed data may change;The above datas are for reference only,please feel free to contact us for the latest data. |